Specifications
Event Reporting: Templates and Codes 5–91
51 The mirrorset is inoperative for one of the following reasons:
■ The last NORMAL member has malfunctioned. Perform repair actions 55 and 59.
■ The last NORMAL member is missing. Perform repair action 58.
■ The members have been moved around and the consistency checks show mismatched members.
Perform repair action 58.
52 The indicated Storageset member was removed for one of the following reasons:
■ The member malfunctioned. Perform repair action 56.
■ By operator command. Perform repair action 57.
53 The STORAGESET may be in a state that prevents the adding of a replacement member, check the state
of the STORAGESET and its associated UNIT and resolve the problems found before adding the
replacement member.
54 The device may be in a state that prevents adding it as a replacement member or may not be large
enough for the STORAGESET. Use another device for the ADD action and perform repair action 57 for the
device that failed to be added.
55 Perform the repair actions indicated in any and all event reports found for the devices that are members
of the STORAGESET.
56 Perform the repair actions indicated in any and all event reports found for the member device that was
removed from the STORAGESET. Then perform repair action 57.
57 Delete the device from the FAILEDSET and redeploy, perhaps by adding it to the SPARESET so it will be
available to be used to replace another failing device.
58 Install the physical devices that are members of the STORAGESET in the proper Port, Target, and LUN
locations.
59 Delete the STORAGESET, recreate it with the appropriate ADD, INITIALIZE, and ADD UNIT commands and
reload its contents from backup storage.
5A Restore the MIRRORSET data from backup storage.
5B The mirrorset is inoperative due to a disaster tolerance failsafe locked condition, as a result of the loss of
all local or remote NORMAL/NORMALIZING members while ERROR_MODE=FAILSAFE was enabled. To
clear the failsafe locked condition, enter the CLI command SET unit-number ERROR_MODE=NORMAL.
5C The mirrorset has at least one local NORMAL/NORMALIZING member and one remote
NORMAL/NORMALIZING member. Failsafe error mode can now be enabled by entering the CLI command
SET unit-number ERROR_MODE=FAILSAFE.
5D The last member of the SPARESET has been removed. Add new drives to the SPARESET.
Table 5–19 Recommended Repair Action Codes (Sheet 4 of 6)
Code Description