37 The Memory System Failure translator could not determine the failure cause. Follow repair action 01.
38 Replace the indicated cache memory DIMM.
39 Check that the cache memory DIMMs are properly configured.
3A This error applies to this controller’s mirrored cache. Since the mirrored cache is physically located on
the other controller’s cache module, replace the other controller’s cache module, or the appropriate
memory DIMMs on the other controller’s cache module.
3C This error applies to this controller’s mirrored cache. Since the mirrored cache is physically located on
the other controller’s cache module, replace the indicated cache memory DIMM on the other controller’s
cache module.
3D Either the primary cache or the mirrored cache has inconsistent data. Check for the following conditions
to determine appropriate means to restore mirrored copies.
■ If the mirrored cache is reported as inconsistent and a previous FRU Utility warmswap of the mirrored
cache module was unsuccessful, retry the procedure via the FRU Utility, by removing the module and
re-inserting the same or a new module.
■ Otherwise, enter the CLI command SHUTDOWN THIS to clear the inconsistency upon reboot.
3E Replace the indicated cache module.
3F No action necessary, cache diagnostics will determine whether the indicated cache module is faulty.
40 If the Sense Data FRU field is non-zero, follow repair action 41. Otherwise, replace the appropriate FRU
associated with the device’s SCSI interface or the entire device.
41 Consult the device’s maintenance manual for guidance on replacing the indicated device FRU.
43 Update the configuration data to correct the problem.
44 Replace the SCSI cable for the failing SCSI bus. If the problem persists, replace the controller backplane,
drive backplane, or controller module.
45 Interpreting the device supplied Sense Data is beyond the scope of the controller’s software. See the
device’s service manual to determine the appropriate repair action, if any.
50 The RAIDset is inoperative for one of the following reasons:
■ More than one member malfunctioned. Perform repair action 55.
■ More than one member is missing. Perform repair action 58.
■ Before reconstruction of a previously replaced member completes another member becomes
missing or malfunctions. Perform repair action 59.
■ The members have been moved around and the consistency checks show mismatched members.
Perform repair action 58.
Table 5–19 Recommended Repair Action Codes (Sheet 3 of 6)
Code Description