Specifications

Event Reporting: Templates and Codes 5–81
20640000
20650000
Nindy was turned
on
.
Applies to
off
.
00
20692010 To enter dual-redundant mode, both controllers must be of the same type. 20
206A0000
206B0010
Controller restart forced by DEBUG CRASH REBOOT command.
Applies to DEBUG CRASH NOREBOOT.
00
206C0020 Controller was forced to restart in order for new controller code image to take effect. 00
206D0000 Controller code load was not completed because the controller could not rundown all units. 00
206E0000 A restart of both controllers is required when entering multibus failover and the last failover
mode of the source controller was transparent, or when entering transparent failover and the
last failover mode of the source controller was multibus.
00
43000100 Encountered an unexpected structure type on hp_work_q. 01
43030100 Unable to allocate the necessary number of large Sense Data buckets in HPP_init( ). 01
43100100 Encountered a NULL completion routine pointer in a DD. 01
43130100 Could not allocate a large sense bucket. 01
43160100 A sense data bucket of unknown type (neither LARGE or SMALL) was passed to
deallocate_SDB( ).
01
43170100 Call to VA$ENABLE_NOTIFICATION( ) failed due to INSUFFICIENT_RESOURCES. 01
43190100 Unable to allocate necessary memory in HPP_int( ). 01
431A0100 Unable to allocate necessary timer memory in HPP_int( ). 01
43210101 HPP detected unknown error indicated by HPT.
Last Failure Parameter [0] contains the error value.
01
43220100 Unable to obtain Free CSR in HPP( ). 01
43230101 During processing to maintain consistency of the data for Persistent Reserve SCSI
commands, an internal inconsistency was detected.
Last Failure Parameter [0] contains a code defining the precise nature of the
inconsistency.
01
44640100 Not enough abort requests in the system. 01
44650100 Exceeded the number of SEST abort retries. 01
Table 5–18 Last Failure Codes (Sheet 35 of 41)
Code Description
Repair
Action
Code