Specifications
5–80 Compaq StorageWorks HSG80 Array Controller ACS Version 8.5 Maintenance and Service Guide
200D0101 After many calls to DS$PORT_BLOCKED, we never got a FALSE status back (which signals
that nothing is blocked).
■ Last Failure Parameter[0] contains the port number (1 - n) that we were waiting on to be
unblocked.
01
200E0101 While traversing the structure of a unit, a config_info node was discovered with an
unrecognized structure type.
■ Last Failure Parameter[0] contains the structure type number that was unrecognized.
01
200F0101 A config_info node was discovered with an unrecognized structure type.
■ Last Failure Parameter[0] contains the structure type number that was unrecognized.
01
20100101 A config_node of type VA_MA_DEVICE had an unrecognized SCSI device type.
■ Last Failure Parameter[0] contains the SCSI device type number that was unrecognized.
01
20110100 An attempt to allocate memory so the CLI prompt messages could be deleted failed. 01
20120101 While traversing the structure of a unit, a config_info node was discovered with an
unrecognized structure type.
■ Last Failure Parameter[0] contains the structure type number that was unrecognized.
01
20130101 While traversing the structure of a unit, the device was of an unrecognized type.
■ Last Failure Parameter[0] contains the SCSI device type that was unrecognized.
01
20160000 In order to go into mirrored cache mode, the controllers must be restarted. 00
20160100 Unable to allocate resources needed for the CLI local program. 01
20170000 In order to go into no mirrored cache mode, the controllers must be restarted. 00
20190010 A cache state of a unit remains WRITE_CACHE_UNWRITTEN_DATA. The unit is not ONLINE,
thus this state would only be valid for a very short period of time.
00
201A0100 An attempt to allocate memory so a CLI prompt message could be reformatted failed. 01
201B0100
201C0100
Insufficient resources to get memory to
lock
CLI.
Applies to
unlock
.
01
20200100 CLI$ALLOCATE_STRUCT( ) could not obtain memory for a new nvfoc_rw_remote_nvmem
structure.
01
20220020 This controller requested this subsystem to poweroff. 00
20260000 With “set failover copy=other”, the controller which is having the configuration copied to will
automatically be restarted via this bugcheck.
00
Table 5–18 Last Failure Codes (Sheet 34 of 41)
Code Description
Repair
Action
Code