Event Reporting: Templates and Codes 5–65
03390108 An unknown interrupt code was found in a device port’s DSPS register.
■ Last Failure Parameter [0] contains the PCB port_ptr value.
■ Last Failure Parameter [1] contains the PCB copy of the device port TEMP register.
■ Last Failure Parameter [2] contains the PCB copy of the device port DBC register.
■ Last Failure Parameter [3] contains the PCB copy of the device port DNAD register.
■ Last Failure Parameter [4] contains the PCB copy of the device port DSP register.
■ Last Failure Parameter [5] contains the PCB copy of the device port DSPS register.
■ Last Failure Parameter [6] contains the PCB copies of the device port
SSTAT2/SSTAT1/SSTAT0/DSTAT registers.
Last Failure Parameter [7] contains the PCB copies of the device port
LCRC/RESERVED/ISTAT/DFIFO registers.
01
033C0101 An invalid code was seen by the error recovery thread in the er_funct_step field of the PCB.
■ Last Failure Parameter [0] contains the PCB er_funct_step code.
01
033E0108 An attempt was made to restart a device port at the SDP DBD.
■ Last Failure Parameter [0] contains the PCB port_ptr value.
■ Last Failure Parameter [1] contains the PCB copy of the device port TEMP register.
■ Last Failure Parameter [2] contains the PCB copy of the device port DBC register.
■ Last Failure Parameter [3] contains the PCB copy of the device port DNAD register.
■ Last Failure Parameter [4] contains the PCB copy of the device port DSP register.
■ Last Failure Parameter [5] contains the PCB copy of the device port DSPS register.
■ Last Failure Parameter [6] contains the PCB copies of the device port
SSTAT2/SSTAT1/SSTAT0/DSTAT registers.
■ Last Failure Parameter [7] contains the PCB copies of the device port
LCRC/RESERVED/ISTAT/DFIFO registers.
01
Table 5–18 Last Failure Codes (Sheet 19 of 41)
Code Description
Repair
Action
Code