Specifications
5–62 Compaq StorageWorks HSG80 Array Controller ACS Version 8.5 Maintenance and Service Guide
02FD0100 The controller has insufficient free memory to restore saved configuration information from
disk.
01
02FE0105 A field in the VSI was not cleared when an attempt was made to clear the interlock.
■ Last Failure Parameter [0] contains the NV index of the VSI on which the problem was
found.
■ Last Failure Parameter [1] contains the contents of the enable_change field of the VSI,
which should be zero.
■ Last Failure Parameter [2] contains the contents of the desired_state field of the VSI,
which should be zero.
■ Last Failure Parameter [3] contains the contents of the completion_routine field of the
VSI, which should be zero.
■ Last Failure Parameter [4] contains the contents of the open_requests field of the VSI,
which should be zero.
01
03010100 Failed request for port-specific scripts memory allocation. 01
03020101 Invalid SCSI direct-access device opcode in misc command DWD.
■ Last Failure Parameter [0] contains the SCSI command opcode.
01
03040101 Invalid SCSI CDROM device opcode in misc command DWD.
■ Last Failure Parameter [0] contains the SCSI command opcode.
01
03060101 Invalid SCSI device type in PUB.
■ Last Failure Parameter [0] contains the SCSI device type.
01
03070101 Invalid CDB Group Code detected during create of misc cmd DWD
■ Last Failure Parameter [0] contains the SCSI command opcode.
01
03080101 Invalid SCSI OPTICAL MEMORY device opcode in misc command DWD.
■ Last Failure Parameter [0] contains the SCSI command opcode.
01
03090101 Failed request for allocation of pci miscellaneous block.
■ Last Failure Parameter [0] contains the failed dwd command class.
01
030A0100 Error DWD not found in port in_proc_q. 01
Table 5–18 Last Failure Codes (Sheet 16 of 41)
Code Description
Repair
Action
Code