Specifications

Event Reporting: Templates and Codes 5–59
02E11016 While attempting to restore saved configuration information, data for two unrelated
controllers was found. The restore code is unable to determine which disk contains the
correct information. The Port/Target/LUN information for the two disks is contained in the
parameter list. Remove the disk containing the incorrect information, reboot the controller,
and issue the SET THIS_CONTROLLER INITIAL_CONFIGURATION command. When the
controller reboots, the proper configuration will be loaded.
Last Failure Parameter [0] contains the first disk port.
Last Failure Parameter [1] contains the first disk target.
Last Failure Parameter [2] contains the first disk LUN.
Last Failure Parameter [3] contains the second disk port.
Last Failure Parameter [4] contains the second disk target.
Last Failure Parameter [5] contains the second disk LUN.
10
02E20100 An attempt to allocate a va_cs_work item from the S_va_free_cs_work_queue failed. 01
02E30100
02E40100
O2E50100
02E60100
02E70100
02E80100
02E90100
02EA0100
An attempt to allocate a free VAR failed. 01
02EB0100 An attempt to allocate a free metadata WARP failed. 01
02EC0101 An online request was received for a unit when both controllers had dirty data for the unit.
The crash is to allow the surviving controller to copy over all of the dirty data.
Last Failure Parameter [0] contains the nv_index of the unit.
01
02ED0100 On an attempt, which is not allowed to fail, to allocate a BDB, no freeable BDB was found. 01
02EE0102 A CLD is already allocated when it should be free.
Last Failure Parameter [0] contains the requesting entity.
Last Failure Parameter [1] contains the CLD index.
01
Table 5–18 Last Failure Codes (Sheet 13 of 41)
Code Description
Repair
Action
Code