Specifications

5–50 Compaq StorageWorks HSG80 Array Controller ACS Version 8.5 Maintenance and Service Guide
011B0108 The I960 reported a machine fault (nonparity error).
Last Failure Parameter [0] contains the Fault Data (2) value.
Last Failure Parameter [1] contains the Fault Data (1) value.
Last Failure Parameter [2] contains the Fault Data (0) value.
Last Failure Parameter [3] contains the Number of Faults value.
Last Failure Parameter [4] contains the PC value.
Last Failure Parameter [5] contains the AC value.
Last Failure Parameter [6] contains the Fault Flags, Type and Subtype values.
Last Failure Parameter [7] contains the RIP value (actual).
01
011C0011 Controller execution terminated via display of solid fault code in OCP LEDs. Note that upon
receipt of this Last Failure in a last gasp message the other controller in a dual controller
configuration will inhibit assertion of the KILL line.
Last Failure Parameter [0] contains the OCP LED solid fault code value.
00
011D0100 Relocated zero (for example, C0000000) entered cia call or branch. 01
018000A0 A powerfail interrupt occurred. 00
018600A0 A processor interrupt was generated with an indication that the other controller in a dual
controller configuration asserted the KILL line to disable this controller.
00
018700A0 A processor interrupt was generated with an indication that the (//) RESET button on the
controller module was depressed.
00
018800A0 A processor interrupt was generated with an indication that the program card was removed. 00
018900A0 A processor interrupt was generated with an indication that the controller inactivity watch
dog timer expired.
00
Table 5–18 Last Failure Codes (Sheet 4 of 41)
Code Description
Repair
Action
Code