Specifications
Event Reporting: Templates and Codes 5–47
Repair Action
The Repair Action code at byte offset 105 indicates the recommended repair action code
assigned to the failure. This value is used during Symptom-Directed Diagnosis procedures
to determine what notification/recovery action should be taken. For details about
recommended repair action codes, see the “Recommended Repair Action Codes” section
on page 5–88.
Error Number
The Error Number is located at byte offset 106. Combining this number with the
Component ID field value uniquely-identifies the reported failure.
Component ID
The component ID is located at byte offset 107. This number uniquely-identifies the
software component that detected the failure. For details about components ID numbers,
see the “Component Identifier Codes” on page 5–93.
Table 5–18 contains the numerous last failure codes, in ascending order, that might be
issued by the controller.
Table 5–18 Last Failure Codes (Sheet 1 of 41)
Code Description
Repair
Action
Code
01000100 Memory allocation failure during executive initialization. 01
01010100 An interrupt without any handler was triggered. 01
01020100 Entry on timer queue was not of type AQ or BQ. 01
01030100 Memory allocation for a facility lock failed. 01
01040100 Memory initialization called with invalid memory type. 01
01082004 The core diagnostics reported a fault.
■ Last Failure Parameter[0] contains the error code value (same as blinking OCP LEDs
error code).
■ Last Failure Parameter[1] contains the address of the fault.
■ Last Failure Parameter[2] contains the actual data value.
■ Last Failure Parameter[3] contains the expected data value.
20