Specifications

Event Reporting: Templates and Codes 5–39
03F20064 The SWAP interrupts have been cleared and re-enabled for all device ports.
Note that in this instance, the Associated Port, Associated Target, Associated
Additional Sense Code, and Associated Additional Sense Code Qualifier
fields are undefined.
41 00
03F30064 An asynchronous SWAP interrupt was detected by the controller for the
device port indicated by the Associated Port field. Possible reasons for this
occurrence include:
device insertion or removal
shelf power failure
SWAP interrupts reenabled
Note that in this instance, the Associated Target, Associated Additional
Sense Code, and Associated Additional Sense Code Qualifier fields are
undefined.
41 00
03F40064 Device services had to reset the port to clear a bad condition.
Note that in this instance, the Associated Target, Associated Additional
Sense Code, and Associated Additional Sense Code Qualifier fields are
undefined.
41 00
03F60402 The controller shelf is reporting a problem. This could mean one or both of
the following:
If the shelf is using dual power supplies, one power supply has failed.
One of the shelf cooling fans has failed.
Note that in this instance, the Associated Target, Associated Additional
Sense Code, and Associated Additional Sense Code Qualifier fields are
undefined.
41 04
03F70401 The shelf indicated by the Associated Port field is reporting a problem. This
could mean one or both of the following:
If the shelf is using dual power supplies, one power supply has failed.
One of the shelf cooling fans has failed.
Note that in this instance, the Associated Target, Associated Additional
Sense Code, and Associated Additional Sense Code Qualifier fields are
undefined.
41 04
Table 5–15 Instance Codes (Sheet 18 of 24)
Instance
Code
Description Template
Repair
Action
Code