Specifications

5–36 Compaq StorageWorks HSG80 Array Controller ACS Version 8.5 Maintenance and Service Guide
03D14002 The identification of a device does not match the configuration information.
The actual device type is unknown to the controller. Note that in this
instance, the Associated Additional Sense Code, and Associated Additional
Sense Code Qualifier fields are undefined.
41 40
03D24402 SCSI bus errors during device operation. The device type is unknown to the
controller. Note that in this instance, the Associated Additional Sense Code
and Associated Additional Sense Code Qualifier fields are undefined.
41 44
03D3450A During device initialization, the device reported the SCSI Sense Key NO
SENSE. This indicates that there is no specific sense key information to be
reported for the designated logical unit. This would be the case for a
successful command or a command that received CHECK CONDITION or
COMMAND TERMINATED status because one of the FM, EOM, or ILI bits is
set to one in the sense data flags field.
41 45
03D4450A During device initialization, the device reported the SCSI Sense Key
RECOVERED ERROR. This indicates the last command completed
successfully with some recovery action performed by the target.
41 45
03D5450A During device initialization, the device reported the SCSI Sense Key NOT
READY. This indicates that the logical unit addressed cannot be accessed.
Operator intervention may be required to correct this condition.
41 45
03D6450A During device initialization, the device reported the SCSI Sense Key MEDIUM
ERROR. This indicates that the command terminated with a non-recovered
error condition that was probably caused by a flaw in the medium or an error
in the recorded data. This sense key may also be returned if the target is
unable to distinguish between a flaw in the medium and a specific hardware
failure (HARDWARE ERROR sense key).
41 45
03D7450A During device initialization, the device reported the SCSI Sense Key
HARDWARE ERROR. This indicates that the target detected a
non-recoverable hardware failure (for example, controller failure, device
failure, parity error, etc.) while performing the command or during a self test.
41 45
Table 5–15 Instance Codes (Sheet 15 of 24)
Instance
Code
Description Template
Repair
Action
Code