Specifications
Event Reporting: Templates and Codes 5–29
02755601 The device specified in the Device Locator field had a read error. Attempts to
repair the error with data from another mirrorset member failed due to a
write error on the original device. The original device will be removed from
the mirrorset.
51 56
02773D01 The mirrored cache is not being used because the data in the mirrored
cache is inconsistent with the data in the primary cache. The primary cache
contains valid data, so the controller is caching solely from the primary
cache. The mirrored cache is declared “failed”, but this is not due to a
hardware fault, only inconsistent data. Mirrored writes have been disabled
until this condition is cleared. Note that in this instance, the Memory
Address, Byte Count, FX Chip register, Memory Controller register, and
Diagnostic register fields are undefined.
14 3D
02782301 The cache backup battery is not present. The Memory Address field contains
the starting physical address of the CACHEA0 memory.
12 23
02792301 The cache backup battery covering the mirror cache is not present. The
Memory Address field contains the starting physical address of the CACHEB1
memory.
12 23
027A2201
027B2201
The
CACHEB0
Memory Controller failed Cache Diagnostics testing
performed on the other cache during a cache failover attempt. The Memory
Address field contains the starting physical address of the
CACHEB0
memory.
Applies to
CACHEB1
.
14 22
027C2201 The CACHEB0 and CACHEB1 Memory Controllers failed Cache Diagnostics
testing performed on the other cache during a cache failover attempt. The
Memory Address field contains the starting physical address of the CACHEB0
memory.
14 22
027D5B01 The Mirrorset associated with the logical unit has gone inoperative due to a
disaster tolerance failsafe locked condition.
51 5B
027F2301 The CACHE backup battery has been declared bad. The battery did not
become fully charged within the expected duration. The Memory Address
field contains the starting physical address of the CACHEA0 memory.
12 23
02825C64 The Mirrorset associated with the logical unit has just had a membership
change such that disaster tolerance failsafe error mode can now be enabled
if desired.
51 5C
Table 5–15 Instance Codes (Sheet 8 of 24)
Instance
Code
Description Template
Repair
Action
Code