Specifications
5–28 Compaq StorageWorks HSG80 Array Controller ACS Version 8.5 Maintenance and Service Guide
0268530A The device specified in the Device Locator field failed to be added to the
RAIDset associated with the logical unit. The device will remain in the
Spareset.
51 53
02695401 The device specified in the Device Locator field failed to be added to the
RAIDset associated with the logical unit. The failed device has been moved
to the Failedset.
51 54
026A5001 The RAIDset associated with the logical unit has gone inoperative. 51 50
026B0064
026C0064
The RAIDset associated with the logical unit has transitioned from
Normal
state to Reconstructing state
.
Applies to
Reconstructing state to Normal state
.
51 00
026D5201 The device specified in the Device Locator field has been removed from the
Mirrorset associated with the logical unit. The removed device is now in the
Failedset.
51 52
026E0001 The device specified in the Device Locator field has been reduced from the
Mirrorset associated with the logical unit. The nominal number of members
in the mirrorset has been decreased by one. The reduced device is now
available for use.
51 00
026F530A The device specified in the Device Locator field failed to be added to the
mirrorset associated with the logical unit. The device will remain in the
Spareset.
51 53
02705401 The device specified in the Device Locator field failed to be added to the
mirrorset associated with the logical unit. The failed device has been moved
to the Failedset.
51 54
02710064 The mirrorset associated with the logical unit has had its nominal
membership changed. The new nominal number of members for the
mirrorset is specified in the Device Sense Data Information field.
51 00
02725101 The Mirrorset associated with the logical unit has gone inoperative. 51 51
02730001 The device specified in the Device Locator field had a read error which has
been repaired with data from another mirrorset member.
51 00
02745A0A The device specified in the Device Locator field had a read error. Attempts to
repair the error with data from another mirrorset member failed due to lack
of alternate error-free data source.
51 5A
Table 5–15 Instance Codes (Sheet 7 of 24)
Instance
Code
Description Template
Repair
Action
Code