Specifications

Event Reporting: Templates and Codes 5–27
025A000A The command failed because the unit became inoperative prior to command
completion. The Information field of the Device Sense Data contains the
block number of the first block in error.
51 00
025B000A The command failed because the unit became unknown to the controller
prior to command completion. The Information field of the Device Sense
Data contains the block number of the first block in error.
51 00
025C000A The command failed because of a unit media format error. The Information
field of the Device Sense Data contains the block number of the first block in
error.
51 00
025D000A The command failed for an unknown reason. The Information field of the
Device Sense Data contains the block number of the first block in error.
51 00
025F2201
02603A01
Memory diagnostics performed during controller initialization detected an
excessive number (512 pages or more) of memory errors detected on the
primary cache memory
. Diagnostics have not declared the cache failed, due
to the isolated bad memory regions, but this is a warning to replace the
cache as soon as possible in case of further degradation. The software
performed the necessary error recovery as appropriate. Note that in this
instance, the Memory Address and Byte Count fields are undefined.
Applies to
mirrored cache memory.
14 22
3A
02613801
02623801
02633801
02643801
Memory diagnostics performed during controller initialization detected that
the DIMM in
location 1
failed on the cache module. Note that in this instance,
the Byte Count field in undefined.
Applies to
location 2
.
Applies to
location 3
.
Applies to
location 4
.
14 38
02653C01
02663C01
Memory diagnostics performed during controller initialization detected that
the DIMM in
location 3
on the other controller’s cache module (on mirrored
cache) failed. Mirroring has been disabled. Note that in this instance, the
Byte Count field is undefined.
Applies to
location 4
.
14 3C
02675201 The device specified in the Device Locator field has been removed from the
RAIDset associated with the logical unit. The removed device is now in the
Failedset. The RAIDset is now in Reduced state.
51 52
Table 5–15 Instance Codes (Sheet 6 of 24)
Instance
Code
Description Template
Repair
Action
Code