Specifications

Event Reporting: Templates and Codes 5–17
ASC/ASCQ Codes
Table 5–12 lists HSG80-specific SCSI ASC and ASCQ codes. These codes are
Template-specific and appear at byte offsets 12 and 13.
NOTE: Additional codes that are common to all SCSI devices can be found in the SCSI
specification.
.
Table 5–12 ASC and ASCQ Codes (Sheet 1 of 3)
ASC Code ASCQ Code Description
04 80 Logical unit is disaster tolerant failsafe locked (inoperative).
3F 85 Test Unit Ready or Read Capacity Command failed.
3F 87 Drive failed by a Host Mode Select command.
3F 88 Drive failed due to a deferred error reported by drive.
3F 90 Unrecovered Read/Write error.
3F C0 No response from one or more drives.
3F C2 NV memory and drive metadata indicate conflicting drive configurations.
3F CE UPS TMW before AC_FAIL.
3F D2 Synchronous Transfer Value differences between drives.
80 00 Forced error on Read.
82 01 No Command control structures available.
84 04 Command failed - SCSI ID verification failed.
85 05 Data returned from drive is invalid.
89 00 Request Sense command to drive failed.
8A 00 Illegal command for pass through mode.
8C 04 Data transfer request error.
8F 00 Premature completion of a drive command.
93 00 Drive returned vendor unique sense data.
A0 00 Last failure event report.
A0 01 Nonvolatile parameter memory component event report.
A0 02 Backup battery failure event report.
A0 03 Subsystem built-in self test failure event report.
A0 04 Memory system failure event report.
A0 05 Failover event report.