Specifications
Event Reporting: Templates and Codes 5–9
Subsystem Built-In Self Test Failure Event Sense Data
Response (Template 13)
The HSG80 controller Subsystem Built-In Self Tests software component reports errors
detected during test execution via the Subsystem Built-In Self Test Failure Event Sense
Data Response (see Table 5–7). The error is signaled to all host systems on all logical
units.
■ ASC and ASCQ codes (byte offsets 12 and 13) are detailed in the “ASC/ASCQ
Codes” section on page 5–17.
■ Instance codes (byte offsets 32–35) are detailed in the “Instance Codes” section on
page 5–20.
104–107 Memory Address
108–159 Reserved
Table 5–6 Template 12—Backup Battery Failure Event Sense Data Response
Format (Continued)
↓ offset bit → 76543210
Table 5–7 Template 13—Subsystem Built-In Self Test Failure Event Sense Data
Response Format
↓ offset bit → 76543210
0 Unused Error Code
1Unused
2 Unused Sense Key
3–6 Unused
7 Additional Sense Length
8–11 Unused
12 Additional Sense Code (ASC)
13 Additional Sense Code Qualifier (ASCQ)
14 Unused
15–17 Unused
18–31 Reserved
32–35 Instance Code
36 Template
37 Template Flags
38–53 Reserved