Specifications
4–52 Compaq StorageWorks HSG80 Array Controller ACS Version 8.5 Maintenance and Service Guide
Use the following steps to test the read and write capabilities of a specific disk drive:
1. From a host console, dismount the logical unit that contains the disk drive you want to
test.
2. Connect a terminal to the controller maintenance port that accesses the disk drive
being tested.
3. Run DILX with the following command:
RUN DILX
IMPORTANT: Use the auto-configure option if testing the read and write capabilities of every
disk drive in the subsystem.
Table 4–21 Data Patterns for Phase 1: Write Test
Pattern Pattern in Hexadecimal Numbers
1 0000
28B8B
3 3333
4 3091
5 0001, 0003, 0007, 000F, 001F, 003F, 007F, 00FF, 01FF, 03FF, 07FF, 0FFF, 1FFF, 3FFF, 7FFF
6 FIE, FFFC, FFFC, FFFC, FFE0, FFE0, FFE0, FFE0, FE00, FC00, F800, F000, F000, C000, 8000, 0000
7 0000, 0000, 0000, FFFF, FFFF, FFFF, 0000, 0000, FFFF, FFFF, 0000, FFFF, 0000, FFFF, 0000, FFFF
8B6D9
9
5555, 5555, 5555, AAAA, AAAA, AAAA, 5555, 5555, AAAA, AAAA, 5555, AAAA, 5555, AAAA, 5555, AAAA,
5555
10 DB6C
11
2D2D, 2D2D, 2D2D, D2D2, D2D2, D2D2, 2D2D, 2D2D, D2D2, D2D2, 2D2D, D2D2, 2D2D, D2D2, 2D2D,
D2D2
12 6DB6
13 0001, 0002, 0004, 0008, 0010, 0020, 0040, 0080, 0100, 0200, 0400, 0800, 1000, 2000, 4000, 8000
14 FIE, FFFD, FFFB, FFF7, FFEF, FFDF, FFBF, FF7F, FEFF, FDFF, FBFF, F7FF, EFFF, BFFF, DFFF, 7FFF
15 DB6D, B6DB, 6DB6, DB6D, B6DB, 6DB6, DB6D, B6DB, 6DB6, DB6D, B6DB, 6DB6, DB6D
16 3333, 3333, 3333, 1999, 9999, 9999, B6D9, B6D9, B6D9, B6D9, FFFF, FFFF, 0000, 0000, DB6C, DB6C
17 9999, 1999, 699C, E99C, 9921, 9921, 1921, 699C, 699C, 0747, 0747, 0747, 699C, E99C, 9999, 9999
18 FFFF