Specifications

4–30 Compaq StorageWorks HSG80 Array Controller ACS Version 8.5 Maintenance and Service Guide
code# is the alpha-numeric value displayed in the entry
code types marked with an asterisk (*) require multiple code numbers
The following examples show the FMU translation of a last-failure code and an instance
code.
Table 4–6 Event-Code Types
Event-Code Type Event-Code Type
ASC_ASCQ_CODE*
COMPONENT_CODE
CONTROLLER_UNIQUE_ASC_ASCQ_CODE*
DEVICE_TYPE_CODE
EVENT _THRESHOLD_CODE
INSTANCE_CODE
LAST_FAILURE_CODE
REPAIR_ACTION_CODE
RESTART_TYPE
SCSI_COMMAND_OPERATION_CODE*
SENSE_DATA_QUALIFIERS*
SENSE_KEY_CODE
TEMPLATE_CODE
FMU>DESCRIBE LAST_FAILURE_CODE 206C0020
Last Failure Code: 206C0020
Description: Controller was forced to restart in order for new controller
code image to take effect.
Reporting Component: 32.(20)
Description: Command Line Interpreter
Reporting component’s event number: 108.(6C)
Restart Type: 2.(02)
Description: Automatic hardware restart
FMU>DESCRIBE INSTANCE 026e0001
Instance Code: 026E0001
Description: The device specified in the Device Locator field has been
reduced from the Mirrorset associated with the logical unit. The nominal
number of members in the mirrorset has been decreased by one. The reduced
device is now available for use.
Reporting Component: 2.(02)
Description: Value Added Services
Reporting component’s event number: 110.(6E)
Event Threshold: 1.(01) Classification:
IMMEDIATE. Failure or potential failure of a component critical to proper
controller operation is indicated; immediate attention is required.