Specifications

4–20 Compaq StorageWorks HSG80 Array Controller ACS Version 8.5 Maintenance and Service Guide
■❍❍●●●❍
E Memory error in the JSRAM. Replace controller.
■❍❍●●●●
F Wrong image found on program card. Replace program card or replace
controller if needed.
■❍●❍❍❍
10 Controller Module memory is bad. Replace controller.
■❍●❍❍●
12 Controller Module memory addressing is
malfunctioning.
Replace controller.
■❍●❍❍●
13 Controller Module memory parity is not
working.
Replace controller.
■❍●❍●❍❍
14 Controller Module memory controller
timer has failed.
Replace controller.
■❍●●❍❍●
15 The Controller Module memory controller
interrupt handler has failed.
Replace controller.
■❍●●●●❍
1E During the diagnostic memory test, the
Controller Module memory controller
caused an unexpected Non-Maskable
Interrupt (NMI).
Replace controller.
■●❍❍●❍❍
24 The card’s code image changed when the
contents were copied to memory.
Replace controller.
■●●❍❍❍❍
30 The JSRAM battery is bad. Replace controller.
■●●❍❍●❍
32 First-half diagnostics of the Time of Year
Clock failed.
Replace controller.
■●●❍❍●●
33 Second-half diagnostics of the Time of
Year Clock failed.
Replace controller.
■●●❍●❍●
35 The processor bus-to-device bus bridge
chip is bad.
Replace controller.
■●●●❍●●
3B There is an unnecessary interrupt
pending.
Replace controller.
■●●●●❍❍
3C There was an unexpected fault during
initialization.
Replace controller.
■●●●●❍●
3D There was an unexpected maskable
interrupt during initialization.
Replace controller.
■●●●●●❍
3E There was an unexpected NMI during
initialization.
Replace controller.
Table 4–4 Flashing OCP Patterns (Continued)
Pattern OCP
Code
Error Repair Action