Table 9-5
Hot-Swap Drive Status LEDs
Activity
Status
(Green)
Drive
Power On
(Green)
Fault Status
(Amber)
Priority Indication
Off X X - No drive activity.
On X X - Drive being accessed.
X Off Off 0 Default.
X On On 1 Ready for removal.
X Slow Off 2 Prepared for operation.
X Off On 3 Device faulty.
X Fast Off 4 Device rebuilding.
X On Fast 5 In failed array.
X Off Slow 6 In critical array.
X Off On 7 Parity check.
X Off Fast 8 Predicted fault.
X Fast On 9 Unconfigured.
X Fast Fast 10 Hot spare.
X On Off 11 Rebuild stopped.
X Fast Slow 12 Identify.