Troubleshooting guide
Using the Storage Subsystem 7-17
Compaq Confidential – Need to Know Required
Writer: Robert Young Project: Compaq AlphaServer DS20E System Comments:
Part Number: ER-K8F6W-UA .A01 File Name: h-ch7 Using the Storage Subsystem.doc Last Saved On: 10/4/99 11:13 AM
Connecting a Single 4-Slot Subsystem
Figure 7-10 displays the connections for a single 4-slot storage subsystem.
Perform the following procedure to connect the storage subsystem:
1. Connect the power source cable ❶ to J1 on the subsystem and the other
end to the power source.
2. Connect the end of the SCSI cable ❷ to one of the SCSI connectors on
the SCSI controller.
3. Connect the other end of the SCSI cable ❷ to J3 (SCSI IN) on the
storage backplane.
4. Terminate the connection at J8 ❸.
CAT0141
J2
J1
J3 J8
J9
Backplane
1
2
3
Figure 7-10. Connections for a Single 4-Slot Subsystem