Installation guide
StorageWorks Secure Path for Windows NT
6-14 123995-002 EK-WNTMP-MH. D01
6.11.2 No Redundant Path Detectable upon Server Boot
If, during server boot, Secure Path finds a StorageWorks RAID Array that has devices
which are accessible through their preferred path, but for which a redundant path cannot
be detected, it will place an Information icon next to the “Subsystem” identifier at the top
of the window. Hovering the cursor over the Information icon (a small blue circle
containing the letter “I”) produces a tool tip, as shown in Figure 6-9, identifying which
subsystem(s) is (are) affected by the missing path. The Information icon will appear next
to all Subsystem identifiers, regardless of which subsystem is affected, to insure that the
user is alerted to the problem. All other Secure Path behavior in this case is identical to
that described in 6.11.1.
Figure 6–9 Secure Path Indicates when Redundant Path is Undetectable