Installation guide
Chapter 5. Installing Secure Path Hardware
EK–WNTMP–MH. D01 123995–002 5–7
5.3.5 Installing an RA8000 or ESA12000 (Fibre Channel) and a Windows NT
Cluster
To establish two individual Fibre Channel loops between clustered Windows NT host
servers and a RAID subsystem, where one bus currently exists, reference Figure 5-5 and
follow these steps:
1. Install the host adapters in the servers
2. Connect the second hub to the second host adapter in each server and to the second
controller.
NOTE
You must use only one set of ports in the controller pair.
3. Reboot the host servers.
The Secure Path solution is now properly prepared and cabled.
Figure 5–5 Secure Path Hardware Interconnect – Fibre Channel Cluster
KGPSA
Fibre Host
Bus
Adapters
Fibre Cable
Fibre Hub
Fibre Cable
SHR-1279
KGPSA
Fibre Host
Bus
Adapters
Additional
Hardware
Windows NT
Server A
Windows NT
Server B
Fibre RA8000 Subsystem
(2 controllers)
5.4 Verify the Secure Path Hardware Configuration
Following system reboot, check the Windows NT system event log for successful start
events for the RaiDisk and HszDisk drivers.