Installation guide

StorageWorks Secure Path for Windows NT
5–6 123995–002 EK–WNTMP–MH. D01
5.3.4 Installing an RA8000 or ESA12000 (Fibre Channel) and One Windows
NT Server
To establish two individual Fibre Channel busses between a single Windows NT host
server and a RAID subsystem, where one bus currently exists, reference Figure 5-4 and
follow these steps:
1. Install the host adapter in the server.
2. Connect the second hub to the second host adapter and to the second controller.
NOTE
You must use only one set of ports in the controller pair.
3. Reboot the host server.
The Secure Path solution is now properly prepared and cabled.
Figure 5–4 Secure Path Hardware Interconnect – Fibre Channel Single Server
KGPSA
Fibre Host
Bus
Adapters
Windows NT
Server
Fibre RA8000
Subsystem
(2 controllers)
Fibre Cable
Fibre Hub
SHR-1278
Additional
Hardware