Troubleshooting guide

Error
Code Error Description Recommended Action
------------------------------------------------------------------------------
1716 - xx Fixed Disk Drive Conditional The following steps apply to error
Format Test codes 1700 - xx through 1717 - 73:
1716 - 01 Exceeded maximum soft error 1. Check the system board jumper
limit. settings and retest
(see Chapter 9, "Jumper and
1716 - 02 Exceeded maximum hard error Switch Settings").
limit. 2. Replace the fixed disk drive
signal and power cables and
1716 - 05 Failed to reset controller. retest.
3. Replace the fixed disk drive
1716 - 06 Fatal error while reading. and retest.
4. Replace the system board and
1716 - 07 Fatal error while writing. retest.
1716 - 08 Failed compare of write/
read buffers.
1716 - 09 Failed to format a cylinder.
1716 - 40 Cylinder 0 failed.
1716 - 42 Failed recalibrate.
1716 - 55 Cylinder 1 error.
1716 - 58 Failed to write sector
buffer.
------------------------------------------------------------------------------
Error
Code Error Description Recommended Action
------------------------------------------------------------------------------
1716 - 59 Failed to read sector The following steps apply to error
buffer. codes 1700 - xx through 1717 - 73:
1716 - 60 Failed to compare sector 1. Check the system board jumper
buffer. settings and retest
(see Chapter 9, "Jumper and
1716 - 65 Exceeded maximum bad sector Switch Settings").
per track. 2. Replace the fixed disk drive
signal and power cables and
1716 - 66 Failed to initialize drive retest.
parameter. 3. Replace the fixed disk drive
and retest.
1716 - 70 Failed translate mode. 4. Replace the system board and
retest.
1716 - 71 Failed nontranslate mode.
1716 - 72 Exceeded maximum bad track
limit.
1716 - 73 Previously exceeded maximum
bad track limit.