Specifications
line failure
1109 - 06 Serial Clock Test, data
line failure
------------------------------------------------------------------------------
Error Error Required
Code Description Action
------------------------------------------------------------------------------
Fixed Disk Drive
17yy - xx
------------------------------------------------------------------------------
1700 - xx Fixed disk drive ID drive The following steps apply to error
test type codes 1700 - xx through 1716 - 59:
1701 - xx Fixed disk drive format 1. Check the fixed disk drive
test controller board for the
proper switch setting
1702 - xx Fixed disk drive read test (see Chapter 8). *
2. Replace the fixed disk drive
1703 - xx Fixed disk drive write/ signal and power cables.
read/compare test 3. Replace the fixed disk drive
controller board. *
1704 - xx Fixed disk drive random 4. Replace the fixed disk drive
seek test assembly.
5. Replace the system board.
1705 - xx Fixed disk drive controller
test * 286 based COMPAQ Personal
Computers only
1706 - xx Fixed disk drive ready test
1707 - xx Fixed disk drive
recalibrate test
1708 - xx Fixed disk drive format bad
track test
1709 - xx Fixed disk drive reset
controller test
1710 - xx Fixed disk drive park head
test
1714 - xx Fixed disk drive file write
test
------------------------------------------------------------------------------
Error Error Required
Code Description Action
------------------------------------------------------------------------------
Fixed Disk Drive
17yy - xx
------------------------------------------------------------------------------
1715 - xx Fixed disk drive head select The following steps apply to error
test codes 1700 - xx through 1716 - 59:
1716 - xx Fixed disk drive conditional 1. Check the fixed disk drive
format test controller board for the
proper switch setting
1716 - 01 Exceeded maximum soft error (see Chapter 8). *
limit 2. Replace the fixed disk drive
signal and power cables.