Specifications

610 - 03 Previously exceeded max 3. Replace the diskette drive
soft error limit power and signal cables.
4. Replace the diskette drive
610 - 04 Previously exceeded max assembly.
hard error limit 5. Replace the system board.
610 - 05 Failed to reset controller * 286 based COMPAQ Personal
Computers only
610 - 06 Fatal error while reading
610 - 07 Fatal error while writing
610 - 08 Failed compare of write/
read/compare
------------------------------------------------------------------------------
Error Error Required
Code Description Action
------------------------------------------------------------------------------
Diskette Drive
6yy-xx
------------------------------------------------------------------------------
6xx - 09 Failed to format a track The following steps apply to all
6yy - xx related error codes.
610 - 10 Failed sector wrap test
1. Check shunt jumper J2 setting
610 - 20 Failed to get drive type on the diskette/tape
controller board (see
610 - 21 ** Failed to get change line Chapter 8). *
status 2. Replace the diskette/tape
controller board. *
610 - 22 Failed to clear change 3. Replace the diskette drive
power and signal cables.
610 - 23 Failed to set drive type in 4. Replace the diskette drive
ID media assembly.
5. Replace the system board.
610 - 24 Failed to read media
* 286 based COMPAQ Personal
610 - 25 Failed to verify media Computers only
610 - 26 Failed to read media in ** The following applies to
speed test 286 based computers:
610 - 27 Failed speed limits For a 1.2 megabyte diskette
drive, replace the diskette
610 - 28 Failed write protect test drive. For a 360 Kbyte
diskette drive, a drive
610 - 29 Failed to read media in modification has not been
file write test performed. See Service
Bulletin 25.
610 - 40 Cylinder 0 Error
------------------------------------------------------------------------------
Error Error Required
Code Description Action
------------------------------------------------------------------------------
Serial
11yy - xx
------------------------------------------------------------------------------
1101 - 01 Serial Port Test, UART The following steps apply to all
DLAB bit failure 11yy - xx related error codes: