Specifications
Cooling Forced air provided by 16 VDC fan
Current 2 amps, maximum at input voltage of 120 VAC,
60 Hz
------------------------------------------------------------------------------
VDC Output: Nominal Current Current Regulation
Voltage Amps Amps Tolerance
VDC Minimum Maximum * Percent
------------------------------------------------------------------------------
+ 5.0 1.5 15.0 2
- 5.0 0.0 0.5 5
+ 12.25 1.0 5.0 2
+ 12.25 0.0 1.5 3
(internal monitor)
- 12.0 0.0 1.0 5
------------------------------------------------------------------------------
* These values are maximum values based on nominal operating conditions for
temperature, line voltage, line frequency, and altitude.
==============================================================================