Service manual
2-2 Service Manual
2.1 Operator Control Panel
Start with the operator control panel (OCP). Check the OCP lights. The
OCP has six status LEDs, three pushbuttons, and a keyswitch.
Figure 2–1 Operator Control Panel
OM29-99
6
1 2 3
4
5
Table 2–1 Operator Control Panel LEDs
Light Color State Meaning
➊ – Run
Green On
Power is supplied to entire system; the
blowers are running. System has exited
console.
➋ – Power
Green On System is powered on.
➌ – Fault
Yellow On Fault on system bus.
➍ – On
Green On Power is supplied to the whole system.
➎ – Secure
Green On
Indicates input from the console device is
prevented.
➏ – Reset
Yellow On Indicates a system reset has occurred,
clearing captured error information.