Service manual

2-2 Service Manual
2.1 Operator Control Panel
Start with the operator control panel (OCP). Check the OCP lights. The
OCP has six status LEDs, three pushbuttons, and a keyswitch.
Figure 2–1 Operator Control Panel
OM29-99
6
1 2 3
4
5
Table 2–1 Operator Control Panel LEDs
Light Color State Meaning
Run
Green On
Power is supplied to entire system; the
blowers are running. System has exited
console.
Power
Green On System is powered on.
Fault
Yellow On Fault on system bus.
On
Green On Power is supplied to the whole system.
Secure
Green On
Indicates input from the console device is
prevented.
Reset
Yellow On Indicates a system reset has occurred,
clearing captured error information.