Service manual
DECevent Error Log 4-39
4.6.2 Machine Check Logout Frames
Machine Check Logout Frame - 670/660
The TL6 Machine Check 670/660 logout frame provides error information to the
operating system error handler. When a fault is detected, PALcode enters a
error handler, captures the state of the processor and system, and builds a
logout frame. One frame is built for both processor and system detected errors.
Machine check logout 670 contain EV6 CPU specific error registers while
machine check logout 660 contains system specific error registers.
63 … 48 47 … 32 31 … 16 15 … 00
Common Area: R|S|D|C| Frame Size 00
System Area Offset CPU Area Offset 08
MCHK Frame Rev MCHK CODE 10
CPU Area: ISTAT 18
DC_STAT 20
C_ADDR 28
DCI_SYNDROME 30
DCO_SYNDROME 38
C_STAT 40
C_STS 48
MM_STAT 50
EXC_ADDR 58
IER_CM 60
I_SUM 68
RESERVED 70
PAL_BASE 78
I_CTL 80
PCTX 88
RESERVED 90
RESERVED 98