Installation guide

Procedure 17
adapters the hose number connections remain the same. (Remember that you
labeled the hoses when removing them from the KFTHAs.)
2.
Remove the five Phillips head screws that hold the card cage and the cable
management rack to the frame (see
).
3.
Pull the shelf out fully.
4.
Remove the top cover by loosening the two quarter-turn screws, lifting the top of
the cover away from the card cage, and then pulling the cover to the right and
off (see
).
5.
Remove any cables attaching I/O devices to the PCI from the front of PCI option
cards. Label each adapter and each shelf or I/O device to which it is connected,
for reinstallation.
6.
Note the slot number from which the option is being moved. Lift each PCI
option from its slot carefully, and place it in an antistatic bag. Label the bag
with the slot number. Also label the bag to indicate the shelf or device to which
it was attached, and label the I/O device(s) to show which devices belong to
each option.
7.
When all PCI option cards have been removed from one shelf, reattach the top
cover and slide it back into the cabinet. Reattach the mounting screws.
8.
Move the PCI option cards and the I/O cables to the new cabinet.
NOTE: If you are transferring more than 12 PCI I/O options, you will need to order
another DWLPB–DA.
Install PCI Modules
1.
Remove the face plates from any slots you plan to use for PCI options. The face
plates are held in place by a Phillips head screw on the inside right front edge of
the card cage.
2.
Insert the option boards.
3.
Attach the hose I/O cable to the proper KFTHA connector and to the PCI card
cage whose contents you just transferred.
NOTE: KFE70-XX and EISA cards are not supported in the GS60E system.