Table 8–6 Electrical Characteristics — All System Variants
Nominal voltage (Vac)
Voltage range (Vac)
temporary condition)
Power source phase
Nominal frequency (Hz)
Frequency range (Hz)
RMS current (max. steady state)
Tower and Rackmount
Single power cord
Multiple power cords
Pedestal
Each power cord
M-Series cab config.-dependent
Nominal voltage (Vac)
Each power cord
100 120 200–240
90–110 110–128 180–250
Single Single Single
50/60 50/60 50/60
49–51/59–61 49–51/59–61 49–51/59–61
11.0 A 8.5 A 5.0 A
6.5 A 5.3 A 3.0 A
12.0 A 10.5 A 7.0 A
100 120 220–240
24 A 24 A 16 A
System Variant
Power Cords
Quantity Length Type
Tower
Pedestal
Rackmount
Cabinet
Up to 3 190 cm (75 in.) IEC 320 C13 to NEMA 5–15
(N. America) or
IEC 320 C13 to country-specific
2 190 cm (75 in.) 120 V nonremovable NEMA 5–15
(N. America) or
200–240 V IEC 320 C13 to
country-specific
3 452 cm IEC 320 C13 to NEMA 5–15
(14 ft. 10 in.) (N. America) or
IEC 320 C13 to IEC 320 C14
(other countries)
2 330 cm 120 V nonremovable NEMA
L5-30P or
(10 ft 10 in.) 200–240 V nonremovable
IEC 309
NOTE: Power supplies are universal, PFC, auto ranging, 100/120/200–240 Vac.