Specifications
7-12 Compaq AlphaServer ES40 Userβs Guide
7.4
SRM Diagnostics
The SRM console event log and SRM console commands help you
troubleshoot problems that do not prevent the system from coming up
to the console.
7.4.1 Console Event Log
A console event log consists of status messages received during power-
up self-tests. If problems occur during power-up, error messages
indicated by asterisks (***) may be embedded in the console event log.
To display a console event log one screen at a time, use the more el
command.
Example 7β2 shows a console event log that shows errors. The console reported
that CPU 1 did not power up and fans 1 and 2 failed.
Example 7β2 Sample Console Event Log
>>> more el
*** Error - CPU 1 failed powerup diagnostics ***
Secondary start error
EV6 BIST = 1
STR status = 1
CSC status = 1
PChip0 status = 1
PChip1 status = 1
DIMx status = 0
TIG Bus status = 1
DPR status = 0
CPU speed status = 0
CPU speed = 0
Powerup time = 00-00-00 00:00:00
CPU SROM sync = 0
*** Error - Fan 1 failed ***
*** Error - Fan 2 failed ***