System information
4-16
AlphaServer 800 Service Guide
set dial
The set dial command sets the dial string to be used when the RMC detects an alert
condition. Note that this string must be in the correct dial string format for the
attached modem. If a paging service is to be contacted, then the dial string must
include the appropriate modem commands to dial the number, wait for the line to
connect, and send the appropriate touch tones to leave a pager message. The dial
string is limited to 31 characters.
Example:
RCM> set dial
dial> ATXDT15085551234
RCM>
set escape
The set escape command allows the user to change the escape sequence used for
exiting pass-through mode and entering console monitor mode. The escape
sequence can be any character string. A typical sequence consists of two or more
control characters for a maximum of 14 characters. It is recommended that control
characters be used in preference of ASCII characters.
Example:
RCM> set escape
new esc> ^[^[rcm
RCM>
set init
The set init command sets the modem initialization string. This string is limited to
31 characters and may be modified depending on the type of modem used. Some
typical initialization strings are:
Modem Initialization String
Motorola 3400 Lifestyle 28.8 at&f0e0v0x0s0=2
AT &T Dataport 14.4/FAX at&f0e0v0x0s0=2
Hayes Smartmodem Optima 288
V-34/V.FC + FAX
at&fe0v0x0s0=2