System information

4-10
AlphaServer 800 Service Guide
disable alert
The disable alert command disables alert conditions from paging an external
operator. Monitoring continues and alerts are still logged in the “last alert” field;
however, alerts are not sent to the remote user.
Example:
RCM> disable alert
RCM>
disable reboot
The disable reboot command disables automatic reboot of the system when the
watchdog timer expires.
Example:
RCM> disable reboot
RCM>
disable remote
The disable remote command disables the remote access to the RMC modem port
and disables the automatic dialing on alert condition detection.
Example:
RCM>disable remote
RCM>
enable alert
The enable alert command enables alert conditions to page an external operator.
Example:
RCM> enable alert
RCM>