System information
4-8
AlphaServer 800 Service Guide
RCM> status
PLATFORM STATUS:
Firmware Revision: V1.0
Server Power: OFF
Fanstate:
System Halt:
Temperature: 29.0 C (warnings at 46 C, power-off at 52 C)
RCM Power Control: ON
Escape sequence: ^[^[RCM
Remote Access: Enabled
Alert Enable: Enabled
Alert Pending: NO
Init String: at&f0e0v0x0s0=2
Dial String: atxdt9,15085553333
Alert String: ,,,,,,5085553332#;
Modem and COM1 baud: 9600
Last Alert: RCM User Requested
Watchdog Timer: 60 seconds
Autoreboot : ON
4.3 Resetting the RMC to Factory Defaults
If you have forgotten the password, or have changed and forgotten the RMC escape
sequence, you can reset the RMC to its factory settings. Use the following procedure
to restore the default settings:
1. Unplug the system line cord from the AC power line.
2. Open the system side panel.
3. Install jumper J22 on the system motherboard (refer to Figure A-1).
4. Plug the system line cord into the AC power line for approximately 15 seconds.
5. Unplug the system line cord from the AC power line.
6. Remove jumper J22.
7. Close the system side panel.
8. Plug the system line cord into the AC power line
NOTE: After resetting to default settings, you should complete the first-time setup
procedures to enable remote dial in and call out alerts.