System information
Server Management Console
4-7
7. Using the RMC command send alert, force an alert condition in order to test the
dial out function and verify proper setup of the modem initialization, dial, and
alert strings.
8. Once the alert is received successfully, use the RMC command clear alert, to
clear the current alert condition and cause the RMC to stop paging the remote
operator. If the alert is not cleared, the RMC continues to page the remote
operator approximately every 30 minutes.
Example: First Time Setup
RCM> status
PLATFORM STATUS:
Firmware Revision: V1.0
Server Power: OFF
Fanstate:
System Halt:
Temperature: 29.0 C (warnings at 46 C, power-off at 52 C)
RCM Power Control: ON
Escape sequence: ^[^[RCM
Remote Access: Disabled
Alert Enable: Disabled
Alert Pending: NO
Init String:
Dial String:
Alert String:
Modem and COM1 baud: 9600
Last Alert:
Watchdog Timer: 60 seconds
Autoreboot : ON
RCM> set init
init> at&f0e0v0x0s0=2
RCM> set dial
dial> atxdt9,15085553333
RCM> set alert
alert> ,,,,,,5085553332#;
RCM> set password
new pass> *********
RCM> enable remote
RCM> enable alert
RCM> send alert
RCM> clear alert