System information
Running System Diagnostics
3-15
3.2.8 kill and kill_diags
The kill and kill_diags commands terminate diagnostics that are currently executing.
NOTE: A serial loopback connector (12-27351-01) must be installed on the COM2
serial port for the kill_diags command to successfully terminate system
tests.
• The kill command terminates a specified process.
• The kill_diags command terminates all diagnostics.
Syntax
kill_diags
kill [PID. . . ]
Argument:
[PID. . . ] The process ID of the diagnostic to terminate. Use the show_status
command to determine the process ID.