Service manual

Firmware Updates D-11
Example D 6 PowerTerm 525 Settings
1. From Start go to Programs and select PowerTerm.
2. At Connect set:
Session type COM
Terminal type VT420-8
Baud Rate 9600
Stop Bits 1
Port Number 1
Parity 8/none
Flow Control Xon/Xoff
click Connect
3. From the Communications menu, select File Transfer Setup and set:
Host Data Type 8-Bit (DOS Ascii)
PC Data Type 8-Bit (DOS Ascii)
click OK
Opening Previously Created Sessions
If the COM1 port KEA session was previously created, open it and from the
Open Session popup, select the name you selected in step 11 of the KEA setup.
If the a PowerTerm 525 session was previously created, open it selecting the
session connecting to the standard I/O module on the GS80/160/320 system.
Changing Baud Rates
Once a connection is established between the laptop/PC and the SCM you may
wish to improve performance by increasing the baud rate of both the standard
I/O terminal port and the COM1 port on the laptop/PC.
First at the SCM prompt:
SCM_E0> set baud 57600
Then make the appropriate KEAterm or PowerTerm changes to set the
connection speed to 57600 also.
Be sure to return the baud rate to 9600 after youve completed your session.