Service manual
Power-Up Diagnostic Error Table C-51
Test#
hex
ERROR #
<15:0>
FRU(s) Component Failure Description
4f See Test 32 (Local DTAG Error line Fault). Same error numbers reported for this Remote
version.
50
Placeholder
51
Placeholder
Memory and directory configuration test
x = Hard QBB_ID where 0<=x<=7
y = Physical MEM Port ID where 0<=y<=3
z = DIR/MEM DIMM ID where 0<=z<=7
n = MEM Array ID where 0<= n<=1
NOTE: ‘CFG’ means MIS-Configuration problem. CFG is NOT a component.
x001 QBBx.DIR
CFG
DIR module not present on QBB x which is
with a GP and MEM in a mult-QBBs system
x0z2 QBBx.DIR J# (#=z+1) CFG QBB x DIR DIMM z type not supported
x003 QBBx.DIR CFG QBB x NUM_DIR_DIMMS <
NUM_MEM_ARRAYS
x0z4 QBBx.DIR.DIM
z
J# (#=z+1) QBB x DIR DIMM z BIST failed
x0z5 QBBx.DIR CFG Empty DIR or none good DIMM in the DIR
x0z6 N/A Placeholder
x007 QBBx.MEM CFG None of MEM present in a single QBB
system
Xyn8 QBBx.MEMy ARRn CFG QBB x MEM y Array n is not fully populated
Xyz9 QBBx.MEMy.D
IMz
J# (#=z+1) CFG QBB x MEM y DIMM z has smaller ranks #
than other DIMMs. (Other DIMMs may have
the same ranks as DIMM k, but only callout
the one with lower DIMM ID.)
XyzA QBBx.MEMy.D
IMz
J# (#=z+1) QBB x MEM y DIMM z rank failed BIST
XynB QBBx.MEMy ARRn CFG QBB x MEM y Array n use 2 of 3 good ranks
XynC QBBx.MEMy ARRn CFG QBB x MEM y Array n DIMMs are not
identical
52
XynD QBBx.MEMy ARRn CFG QBB x MEM y Array n DIMM type is not
support