Service manual

C-50 AlphaServer GS80/160/320 Service Manual
Test#
hex
ERROR #
<15:0>
FRU(s) Component Failure Description
FC#x
System box:
HSW0
QBBx.GP.CBL
Drawer:
SCBL
QBBx.CBL
QBBx is
REMOTE QBB
X=1..6 Scratch Test failed. Parity errors
detected on HS CSRs
47
contin
ued
FF#x
System box:
HSW0
QBBx.GP.CBL
Drawer:
SCBL
QBBx.CBL
QBBx is
REMOTE QBB
X=1..6 Scratch Test failed. Parity errors
detected on HS and GP CSRs.
48 See Test 2b (Local IOP BIST check test). Same error numbers reported for this remote.
49 See Test 2c (Local QSA Error line). Same error numbers reported for this remote version.
4a See Test 2d (Local Hose Error line). Same error numbers reported for this remote version.
4b See Test 2e (Local GP Error line). Same error numbers reported for this remote version except
as follows:
Error # 0099 == NO Global Port is present in this QBB UNDER TEST!! (note: This error will
be flagged in powerup or user mode even though its really only useful in User mode debug)
Parameters for error number 0099
P1: QSA_QBB_POP_1 info (passed to XSROM from PSM NOT read from the CSR)
P2: Target HARD_QBB_UNDER_TEST
P3: unused
P4: unused
4c Placeholder
4d See Test 30 (Local DIR Error line). Same error numbers reported for this remote version
except as follows:
Error # 0099 == NO DIRectory Module is present in this QBB UNDER TEST!! (note: This
error will be flagged in powerup or user mode even though its really only useful in User mode
debug)
Parameters for error number 0099
P1: QSA_QBB_POP_1 info (passed to XSROM from PSM NOT read from the CSR)
P2: Target HARD_QBB_UNDER_TEST
P3: unused
P4: unused
4e See Test 31 (Local QSD Error line Fault). Same error numbers reported for this Remote
version.