Service manual

Power-Up Diagnostic Error Table C-47
Test#
hex
ERROR #
<15:0>
FRU(s) Component Failure Description
41 See Test 24 (Local IOP Error). Same error numbers reported for this remote version.
See Test 25 (Local MEM0 Scratch/BIST/Error test). Same error numbers reported for this
remote version.
See Test 26 (Local MEM1 Scratch/BIST/Error). Same error numbers reported for this remote
version.
See Test 27 (Local MEM2 Scratch/BIST/Error). Same error numbers reported for this remote
version.
See Test 28 (Local MEM3 Scratch/BIST/Error). Same error numbers reported for this remote
version.
QBBx is the Target QBB under test.
The following errors are in addition to those documented for the local test 25 28.
F300
System box:
QBBx.GP.CBL
HSW0
QBBx.GP
Drawer:
QBBx.CBL
SCBL, QBBx
QBBx is
REMOTE QBB
Scratch testing passed but parity errors
detected on GP CSRs
FC00
System box:
HSW0
QBBx.GP.CBL
Drawer:
SCBL
QBBx.CBL
QBBx is
REMOTE QBB
Scratch testing passed but parity errors
detected on HS CSRs
FF00
System box:
HSW0
QBBx.GP.CBL
Drawer:
SCBL
QBBx.CBL
QBBx is
REMOTE QBB
Scratch testing passed by parity errors
detected on GP and HS CSRs
42
43
44
45 (3
sub-
tests)
F3#x
System box:
QBBx.GP.CBL
HSW0
QBBx.GP
Drawer:
QBBx.CBL
SCBL, QBBx
QBBx is
REMOTE QBB
X=1..6 Scratch Test failed. Parity errors