Service manual
Power-Up Diagnostic Error Table C-47
Test#
hex
ERROR #
<15:0>
FRU(s) Component Failure Description
41 See Test 24 (Local IOP Error). Same error numbers reported for this remote version.
See Test 25 (Local MEM0 Scratch/BIST/Error test). Same error numbers reported for this
remote version.
See Test 26 (Local MEM1 Scratch/BIST/Error). Same error numbers reported for this remote
version.
See Test 27 (Local MEM2 Scratch/BIST/Error). Same error numbers reported for this remote
version.
See Test 28 (Local MEM3 Scratch/BIST/Error). Same error numbers reported for this remote
version.
QBBx is the Target QBB under test.
The following errors are in addition to those documented for the local test 25 – 28.
F300
System box:
QBBx.GP.CBL
HSW0
QBBx.GP
Drawer:
QBBx.CBL
SCBL, QBBx
QBBx is
REMOTE QBB
Scratch testing passed but parity errors
detected on GP CSRs
FC00
System box:
HSW0
QBBx.GP.CBL
Drawer:
SCBL
QBBx.CBL
QBBx is
REMOTE QBB
Scratch testing passed but parity errors
detected on HS CSRs
FF00
System box:
HSW0
QBBx.GP.CBL
Drawer:
SCBL
QBBx.CBL
QBBx is
REMOTE QBB
Scratch testing passed by parity errors
detected on GP and HS CSRs
42
43
44
45 (3
sub-
tests)
F3#x
System box:
QBBx.GP.CBL
HSW0
QBBx.GP
Drawer:
QBBx.CBL
SCBL, QBBx
QBBx is
REMOTE QBB
X=1..6 Scratch Test failed. Parity errors
detected on GP CSRs.