Service manual

Power-Up Diagnostic Error Table C-21
Test
# hex
ERROR #
<15:0>
FRU(s) Component(s) Failure Description
FF00
System box:
HSW0
QBBx.GP.CBL
Drawer:
SCBL,
QBBx.CBL
QBBX is
LOCAL QBB
Scratch testing passed by parity errors detected
on GP and HS CSRs
F3#x
System
box:QBBx.GP.
CBL
HSW0
QBBx.GP
Drawer:
QBBx.CBL
SCBL, QBBx
QBBx is
LOCAL QBB
X=1..6 Scratch Test failed. Parity errors
detected on GP CSRs.
FC#x
System box:
HSW0
QBBx.GP.CBL
Drawer:
SCBL,
QBBx.CBL
QBBx is
LOCAL QBB
X=1..6 Scratch Test failed. Parity errors
detected on HS CSRs
FF#x
System box:
HSW0
QBBx.GP.CBL
Drawer:
SCBL,
QBBx.CBL
QBBx is
LOCAL QBB
X=1..6 Scratch Test failed. Parity errors
detected on HS and GP CSRs.
#0#x
System box:
QBBx,GP
QBBX.GP.CBL
QBBx.CPUy
HSW0
Drawer:
QBBx
QBBx.CBLE
SCBL
QBBx.CPUy
GPA, GPD0
GPDz
(z=0,1,2,3)
GP,QSDz
(z=0,1,2,3)
X=1..6 Scratch Test failed. No parity errors
detected.
0099 HSW0 / SCBL QSA_QBB_POP_1<hs_ready> bit is NOT set
22
contin
ued
7777 FRU not
determined
GPA CSR (8-bits) Read had bits other than
<7:0> set! Possibly bad GP cable.