Service manual

GS160/320 Component Removal and Replacement 4-21
Each module placed in a QBB is color-coded to correspond to both system box
and drawer color-coded slots. Table 47 lists the modules and their associated
color codes. Figure 44 shows slot location color codes for both system boxes
and drawers.
For system box systems, QBBs located at the front of system cabinets have
global port slots located on the rear of the backplane. Note that the system box
orientation depends upon where the box is relative to the hierarchical switch.
In Figure 41, the orientation of system boxes with QBBs 0 and 2 is rotated 180
0
for QBBs 4 and 6. Also note global ports for both back and front QBBs can only
be seen at the back of the machine.
For drawer systems, the color codes shown in Figure 44 apply to the modules
in both drawers though the slot location is slightly different from the slot
location in system boxes. Separate global port modules are not necessary for
drawer systems since the global port function is designed into the drawer
backplane.