Service manual

Troubleshooting 3-101
Firmware Rev : -
Site Location : -
Cabinet Id : Firebox Power Cabinet
Position : Front, Second from Top
Chassis : -
Assembly : Power Subrack
Subassmbly : -
Slot : Ps1 Ps2 Ps3
Evidence:
Time Event was Logged : Thu, 27 Jan 2000 06:59:34 -0500
Time Event Occurred : 27 Jan 2000 11:55:19
Unique ID Count : 0
Unique ID Prefix : 27392
Rule Revision : x1.0
The brief description summarizes the problem. In this case the problem is
that there is not enough power to keep the two QBBs in the system box
running. (Though not called out at this level, this error is a 680 machine
check.)
The full description of the problem gives more detail. Power subrack 2 and
its power supplies are identified as faulty.
The FRUs and their location are identified.
The supporting evidence can be seen in the error log that occurred at the
date and time specified. The event has the unique ID prefix of 27392. You
can use Compaq Analyze to view that event.