Service manual
Troubleshooting 3-69
Example 3– 46 Isa_misc_diag
P01>>> set d_trace on |
P01>>> set d_group mfg |
P01>>> set d_harderr continue |
P01>>> isa_misc_diag -h 12
isa_misc_dia 00000083 Std-I/O H12 1 1 0 0 12:00:01
isa_misc_dia 00000083 Std-I/O H12 1 2 0 0 12:00:01
isa_misc_dia 00000083 Std-I/O H12 1 3 0 0 12:00:01
The set d_trace command causes the diagnostic output to display on the
console. The set d_group mfg command permits the test to be run. The
set d_harderr continue command causes the diagnostic to continue
running even after a hard error.
The isa_misc_diag – h 46 command causes the console to run the
miscellaneous diagnostic tests on the ISA bus. In this case the standard
I/O module being tested is on PCI hose 12.
The generic syntax is:
isa_misc_diag -h <dev. ID> -t<test#> –p<pass count>
Tests 1 through 3 run.
Test 1 = shared RAM pattern test
Test 2 = standard I/O EEPROM test
Test 3 = standard I/O module CSR test
The diagnostic does not have a hard or soft failure.