3-68 AlphaServer GS80/160/320 Service Manual
Example 3– 45 Bq4285_diag
P01>>> set d_trace on |
P01>>> set d_group mfg |
P01>>> set d_harderr continue |
P01>>> bq4285_diag -h 12
bq4285_diag 0000007e bq4285 H12 1 1 0 0 12:00:01
bq4285_diag 0000007e bq4285 H12 1 3 0 0 12:00:01
bq4285_diag 0000007e bq4285 H12 1 4 0 0 12:00:01
bq4285_diag 0000007e bq4285 H12 1 5 0 0 12:00:01
The set d_trace command causes the diagnostic output to display on the
console. The set d_group mfg command permits the test to be run. The
set d_harderr continue command causes the diagnostic to continue
running even after a hard error.
The bq4285_diag – h 12 command causes the console to run the diagnostic
test suite on the real-time clock. In this case the standard I/O module being
tested is on PCI hose 12.
The generic syntax is:
bq4285_diag -h <dev. ID> -t<test#> –p<pass count>
Tests 1 through 5 run on the real-time clock.
The diagnostic does not have a hard or soft failure.