3-24 AlphaServer GS80/160/320 Service Manual
3.5 Running Diagnostics Using the SCM Monitor
If the SRM console gets loaded, the SROM/XSROM diagnostic tests
cannot be run under the console. To run SROM/XSROM diagnostics in
SCM user mode they must be loaded and remain in the CPUs I-cache or
B-cache. And once XSROM tests are loaded into a CPUs B-cache,
SROM tests may not be run on it unless the SROM is once again loaded.
SCM examines and deposits require SROM or XSROM code running.
Example 3 12 Setting Up the Diagnostic Environment and Testing
SCM_E0> show nvram
COM1_PRINT_EN
HP_COUNT 0
.
.
.
SROM_MASK ff f
XSROM_MASK ff ff ff ff ff ff ff ff ff 1 0 0
.
.
.
AUTO_FAULT_RESTART 1
SCM_SIZING_TIME c
SCM_E0> test &pc0 5
Testing. Please wait..CPU Connect Error node 30(response=2e)
SCM_E0> set xsrom_mask none
SCM_E0> sho nvram
ALERT Uninitialized
BAUD 57600
.
.
.
SROM_MASK fe f
XSROM_MASK 0 0 0 0 0 0 0 0 0 0 0 0
.
.
.
SCM_CSB_MASTER_ELIGIBLE 1
PERF_MON 0