Service manual
3-22 AlphaServer GS80/160/320 Service Manual
3.4.5 Dealing With EEPROMs
EEPROMs throughout the system record FRU identification and error
information and store system environment and firmware information.
Example 3– 8 Clear error
SCM_E0> show fru
.
.
.
QBB1.DIR0.DIM7 00 ...S...S...S@..... ??404?6T$$ v....".... .G...H......_ ’.
QBB1.GP 00 B4181-BA. B01 NI93061440 .......... ................
QBB2 00 54-25043-01.D03 NI94470368
QBB2.PSM 40 54-25074-01.J01 NI94570274 WF96LTA113 WF_FIRMWARE_LAB
QBB2.PWR 00 54-25017-01.F01 NI94171317
QBB2.AUX 00 54-25123-01.E01 NI94170839
.
.
.
scm-E0> clear error qbb2.psm
scm_E0> show fru
.
.
.
QBB1.DIR0.DIM7 00 ...S...S...S@..... ??404?6T$$ v....".... .G...H......_ ’.
QBB1.GP 00 B4181-BA. B01 NI93061440 .......... ................
QBB2 00 54-25043-01.D03 NI94470368
QBB2.PSM 00 54-25074-01.J01 NI94570274 WF96LTA113 WF_FIRMWARE_LAB
QBB2.PWR 00 54-25017-01.F01 NI94171317
QBB2.AUX 00 54-25123-01.E01 NI94170839
Example 3–8 is an example of the clear error command. In this case, the
command clears the error logged against the PSM module in QBB2.