QuickSpecs

System Unit
System UnitSystem Unit
System Unit
Dimensions
DimensionsDimensions
Dimensions
(H x W x D)
(with bezel)
1.70 x 16.78 x 27.25 in (4.32 x 42.62 x 69.22 cm)
Weight
WeightWeight
Weight
(approximate)
Maximum
(all hard drives, power
supplies, and processors
installed)
39.5 lb (17.92 kg)
Minimum
(one hard drive, power
supply, and processor
installed)
32 lb (14.51 kg)
Input Requirements
Input RequirementsInput Requirements
Input Requirements
(for Standard 460W PSU,
see power specifications
tables for detail on 460W,
750W and 1200W power
supplies)
Rated Line Voltage
100 to 240 VAC
Rated Input Current
4.5 Amps (at 120VAC) to 2.2 Amps (at 240
VAC)
Rated Input Frequency
50 to 60 Hz
BTU Rating
BTU RatingBTU Rating
BTU Rating
Maximum
1773 BTU / hr (at 120 VAC), 1715 (at 240
VAC)
Power Specifications
Power SpecificationsPower Specifications
Power Specifications
To review typical system power ratings use the HP Power Advisor which is
available via the online tool located at URL:
www.hp.com/go/proliant-
energy-efficient
or
www.hp.com/go/hppoweradvisor
- Click on the system of interest. Example: DL360 G7
- Follow the instructions of the next screens.
Power Supply Output
Power Supply OutputPower Supply Output
Power Supply Output
(per power supply)
Rated Steady-State Power
460 W (at 100 VAC),
460 W (at 200 VAC)
Maximum Peak Power
460 W (at 100 VAC),
460 W (at 200 VAC)
NOTE:
NOTE:NOTE:
NOTE:
See Power Supply Specifications tables
for complete details on 460W PSU and optional
750W and 1200W Power Supply Options.
System Inlet Temperature
System Inlet TemperatureSystem Inlet Temperature
System Inlet Temperature
Operating
10° to 35° C (50° to 95° F) at sea level with an
altitude derating of 1.0°C per every 305 m (1.8°
F per every 1000 ft) above sea level to a
maximum of 3050 m (10,000 ft), no direct
sustained sunlight. Maximum rate of change is
10° C/hr (18° F/hr). The upper limit may be
limited by the type and number of options
installed.
System performance may be reduced if operating
with a fan fault or above 30° C (86° F).
Non-operating
-40° to 70° C (-40° to 158° F). Maximum rate of
change is 20° C/hr (36° F/hr).
Relative Humidity
Relative HumidityRelative Humidity
Relative Humidity
(non-condensing)
Operating
10 to 90% relative humidity (Rh), 28° C (82.4° F)
maximum wet bulb temperature, non-
condensing.
QuickSpecs
HP ProLiant DL360 Generation 7 (G7)
HP ProLiant DL360 Generation 7 (G7)HP ProLiant DL360 Generation 7 (G7)
HP ProLiant DL360 Generation 7 (G7)
Technical Specifications
DA - 13598 Worldwide — Version 2 — May 17, 2010
Page 47